Vajad kellegagi rääkida?
Küsi julgelt abi LasteAbi
Logi sisse
Sulge

"calibrated" - 8 õppematerjali

Study of heat transfer coefficient in helical coil
52
docx

Study of heat transfer coefficient in helical coil

2 Experimental description 2.1 Experimental apparatus The experiments were carried out in the experimental apparatus, whose schematic diagram is shown in Figure 2. Figure 2: Schematic diagram of the apparatus The water used to flow through the steel coil was held in a reservoir, with a capacity of approximately 25 liters. A centrifugal pump was used to circulate the water from the tank to the coil and then to the drain. The flow rate of the water was measured using a calibrated rotameter. The coil was located inside the hot water rectangular bath with dimensions of 45,5 X 21,1 cm with no baffles. The height of the coil was 6,2 cm, the diameter of helix was 17,4 cm, the length of the tube in spiral was 4,72 m, and the internal diameter of the tube was 7,3mm and external diameter 1,1cm. The bath was heated with a Bioblock Scientific polystat microprocessor controlled electrical resistance. The agitation system was composed by a

Varia → Kategoriseerimata
2 allalaadimist
Kolloid- ja pindnähtuste keemia
23
doc

Kolloid- ja pindnähtuste keemia

liquid or gas colloid. A nephelometer measures suspended particulates by employing a light beam (source beam) and a light detector set to one side (often 90°) of the source beam. Particle density is then a function of the light reflected into the detector from the particles. To some extent, how much light reflects for a given density of particles is dependent upon properties of the particles such as their shape, color, and reflectivity. Nephelometers are calibrated to a known particulate, then use environmental factors (k-factors) to compensate lighter or darker colored dusts accordingly. K-factor is determined by the user by running the nephelometer next to an air sampling pump and comparing results. Nefelomeeter [1] on statsionaarne või portatiivne instrument kontsentratsiooni mõõtmiseks tahkete osakeste vedelik või gaas kolloid.Nefelomeeter meetmed hõljuvainete kasutades valgusvihu

Keemia → Kolloidkeemia
24 allalaadimist
Metroloogia ja mõõtetehnika
16
pdf

Metroloogia ja mõõtetehnika

Kalibreerimistulemust saab väljendada kirjelduse, kalibreerimisfunktsiooni, -diagrammi, -kõvera, või -tabeli kujul. Mõnel juhul võib see koosneda näidu aditiivsetest paranditest või parandusteguritest koos vastava mõõtemääramatusega. Kahe etaloni võrdlust võib vaadelda kalibreerimisena, kui võrdluse alusel kontrollitakse ja vajadusel korrigeeritakse ühele etalonidest omistatud suuruse väärtust ja mõõtemääramatust. Three main reasons for having an instrument calibrated: 1. To ensure readings from the instrument are consistent with other measurements. 2. To determine the accuracy of the instrument readings. 3. To establish the reliability of the instrument i.e. that it can be trusted. 10. MÕÕTÜHIKU JÄLGITAVUS. JÄLGITAVUSAHEL TÖÖMÕÕTEVAHENDI KALIBREERIMISEL Metroloogiline jälgitavus, metrological traceability - Mõõtetulemuse omadus, mille abil saab seda tulemust

Metroloogia → Metroloogia ja mõõtetehnika
321 allalaadimist
Book Analog Interfacing to Embedded Microprocessors
568
pdf

Book Analog Interfacing to Embedded Microprocessors

determine the actual temperature. You would want to look at storing this calibration with the sensor if it is not physically located with the microprocessor. This way, the sensor can be changed without recalibrating. Figure 1.1 shows three means of handling this calibration. In diagram A, a microprocessor connects to a remote sensor via a cable. The microprocessor stores the calibration information in its EEPROM or flash memory. The tradeoffs for this method are: • Once the system is calibrated, the sensor has to stay with that micro- processor board. If either the sensor or the microprocessor is changed, the system has to be recalibrated. • If the sensor or microprocessor is changed and recalibration is not performed, the results will be incorrect, but there is no way to know that the results are incorrect unless the microprocessor has a means to identify specific sensors. • Data for all the sensors can be stored in one place, requiring less memory than other methods

Mehhatroonika → Mehhatroonika
11 allalaadimist
Inglise keel unit 5 answers
276
docx

Inglise keel unit 5 answers

(ii) 1 ACFOR scale converted to numerical scale; 2 reading at each site recorded (on graph paper); 3 width of diagram related to ACFOR (maybe shown on diagram); 4 points from each site joined together; 5 repeated for each species found present; max 3 (c) use of, thermometer / probe; probe must be calibrated; pushed into, sand / soil, to same depth each time; repetitions at each sampling point; max 2 (d) (i) a stage during the process of succession; 1 (ii) sea couch / marram grass, grow in bare sand; dune builds up / stabilised by grasses; OR colonisers established on bare, rock / soil;

Keeled → Inglise keel
13 allalaadimist
CPM1A Programmable Controllers Operation Manual 1784470
402
pdf

CPM1A Programmable Controllers Operation Manual 1784470

following precautions: • Do not remove the cold junction compensator attached at the time of deliv- ery. If the cold junction compensator is removed the Unit will not be able to measure temperatures correctly. • Each of the input circuits is calibrated with the cold junction compensator attached to the Unit. If the Unit is used with the cold junction compensator from other Units, the Unit will not be able to measure temperatures correct- ly. xix

Tehnika → Automatiseerimistehnika
9 allalaadimist
Ford escorti käsiraamat
256
pdf

Ford escorti käsiraamat

Central Fuel Injection (CFI) engine emission control system is used of which the manifold and by another to the air cleaner. models exact components fitted can vary according The gas flow is controlled by a calibrated port to model. In general the system operates as To minimise the escape of unburned in the oil filler cap and by manifold vacuum follows. hydrocarbons, the fuel tank filler cap is sealed, according to throttle position.

Auto → Auto õpetus
107 allalaadimist
Liha töötlemine
1168
pdf

Liha töötlemine

Before” dates) Measurement of 20% of batch Check temperature Temperature of meat meat temperature against calibrated (<−12°C) thermometer Data record analysis Storage of raw Temperature of frozen CP-GHP/ Frozen room temp

Keeled → Inglise keel
22 allalaadimist


Sellel veebilehel kasutatakse küpsiseid. Kasutamist jätkates nõustute küpsiste ja veebilehe üldtingimustega Nõustun