SUUR KASUTEGUR PUMPA ISELOOMUSTAVAD SUURUSED TOOTLIKKUS (l/sek või l/min) VÄLJASTATAV RÕHK (kPa või bar) IMIKÕRGUS (m) VÕIMSUS (Kw) KASUTEGUR (%) TULETÕRJEPUMPADE TOOTLIKKUSEKS ON KESKMISELT 2000-4000 l/min 10bar JUURES TULETÕRJEPUMBAD ON ENAMUSES NORMAALSURVEPUMBAD MEIE TÖÖS KASUTATAVAD PUMBAD SURVEPUMP (tsentrifugaalpump) VAAKUMPUMP (kolbpump/membraanpump) SUKELPUMP (tsentrifugaal/propellerpump) EJEKTORPUMP (imi-jugapump) UJUVPUMP VAAKUMPUMP ENAMLEVINUD PUMP VEE IMEMISE TOETAMISEKS TSENTRIFUGAALPUMPA KOLBPUMP MEMBRAANPUMP VAAKUMSEADE KASUTATAKSE VAID HÕRENDUSE TEKITAMISEKS KUI VESI PUMBAS, LÜLITATAKSE VÄLJA VAAKUMPUMP MIDA VEE IMEMISEL JÄLGIDA VEE IMEMISE AJAL EI TOHI PUMPA SATTUDA ÕHKU SÕELA OTS EI TOHI OLLA PÕHJALE LÄHEMAL KUI 0,8 VOOLIKU SISELÄBIMÕÕTU IMIVOOLIK PEAB PUMBA POOLE PIDEVALT TÕUSMA, ET VÄLTIDA
Vaakum tekitatakse magestisse ejektoriga, pumbates sellest läbi merevett mereveepumbaga. Pumbaks on horisontaalne üheastmeline tsentrifugaalpump (Q=35m3/h; n=2300p/min; N=8kW). Destillaadi väljapumpamiseks on tsentrifugaalpump. Magestusprotsessil ülejäänud soolvesi pumbatakse magestist välja ejektoriga. Magesti käivitamine: - avada ejektorpumba imi- ja surveventiil - sulgeda vaakumventiil magesti peal - käivita ejektorpump - vaakumi tõusmisel 90%-ni, avada sujuvalt kuumavee kraanid peamasinatelt tsirkulatsioonipumbale ja aurustile 69 - Kui vaakum on uuesti jõudnud 90%-ni, käivitada destillaadipump - Lülitada sisse salinomeeter - avada mereveelisandi „vapter“ doseerimise kraan, doos reguleerida 20ml - töö ajal jälgida vee taset alumises klaasis Magesti seiskamine: - välja lülitada salinomeeter