...................................................................................8 Soojusagensise mahtkulu:.......................................................................................................8 Torude arv...............................................................................................................................9 Torude arv soojusvahetis:........................................................................................................9 Torukimbu ehk Bundle'i diameeter........................................................................................9 Korpuse diameeter................................................................................................................10 Soojusagensise soojusülekandetegur (h0).............................................................................12 Soojusläbikandetegur......................................................................................................
Soojusvaheti Arvutada joonisel kujutatud kahekäigulise horisontaalse aur - vesi manteltoru-soojusvaheti soojusvahetuspind, kui nõutav küttevõimsus on Q, vee temperatuur enne soojusvahetit t v' ja pärast soojusvahetit tv", auru rõhk p on esitatud manomeetri näidu järgi. Õhurõhu väärtuseks lugeda 0,1 MPa. Soojusvaheti torude materjal valida lähteandmete tabelist. Torud valida välisläbimõõduga 20 mm ja seinapaksusega 2 mm. Torukimbu pikkusena mõeldakse boilerisse paigutatud torude pikkust l = 2 m joonisel. Soojusvahetuspind esitada torude arvuna boileris. Lihtsuse mõttes võib metalli soojusjuhtivusteguri lugeda temperatuurist sõltumatuks suuruseks ja valida käsiraamatu abil torude keskmise temperatuuri järgi. Algandmed: Q=900 kW p=1,4 Mbar d=0,016m tv´´=180°C λm=110,7 W/m*K tv=125°C