Tolereerimise valemid
4
docx

Tolereerimise valemid

shaft Võlli tolerants Td = dmax - dmin TS = GuS - GlS Lõtkist Parameeter ISO 286-1E:2009 ISO 286-1:2010 Maksimaalne lõtk Cmax = Dmax - dmin FCmax = GuH - GlS Minimaalne lõtk Cmin = Dmin – dmax FCmin = GlH – GuS Keskmine lõtk Cmean = (Cmax + FCmean = (FCmax + Cmin)/2 FCmin)/2 Istu tolerants Tfit = Cmax – Cmin TF = FCmax – FCmin Tfit = TD + Td TF = TH + TS Pingist Parameeter ISO 286-1E:2009 ISO 286-1:2010 Maksimaalne ping Imax = dmax - Dmin FImax = GuS - GlH Minimaalne ping Imin = dmin – Dmax FImin = GlS – GuH Keskmine ping Imean = (Cmax + FImean = (FCmax + Cmin)/2 FCmin)/2 Istu tolerants Tfit = Cmax – Cmin TF = FCmax – FCmin

Auto → Tolereerimine ja...
28 allalaadimist
ISTU ARVUTUS
8
docx

ISTU ARVUTUS

d¿ 0,033 Keskmine ping M ∈¿ IMean = ( I M ax −C¿ )/2 =(0,008-0,017)/2=- 0,0045 Maksimaalne lõtk CMax = DMax – dMin =32,025-31,992=0,033 Minimaalne lõtk C Min = D Min−d Max =32-31,992=0,008 Istu tolerants Tfit = TD + Td =0,025+0=0,025 2.4 Istu skemaatiline kujutamine Sele 2.1 Istu skemaatiline kujutamine 2.5 Kokkuvõte Lähteülesandes antud ist on avasüsteemis, sest ava ülemine piirhälve on + ja alumina 0, ehk ava tolerantsitsoon toetub nulljoonele ülevaltpoolt. Istu tolerantsitsoonide skeem on esitatud selel 2.1. Selel on näidatud maksimaalne ping ja maksimaalne lõtk, mis antud istu korral võib piirolukordades ette tulla. 2.6 Järeldus

Masinaehitus → Mõõtmestamine ja...
103 allalaadimist