Cpm1a - 30CDR-j(-V1)/30CDT-j(-V1)/30CDT1-j(-V1) CPU Units 120 mm CPM1A-40CDR-j(-V1)/40CDT-j(-V1)/40CDT1-j(-V1) CPU Units 140 mm Expansion p I/O Units CPM1A-20EDj 76 mm CPM1A-8Ej 56 mm Analog g I/O Unit CPM1A-MAD01 56 mm CPM1A-MAD11 76 mm CompoBus/S I/O Link Unit 56 mm DeviceNet I/O Link Unit 56 mm RS-232C Adapter 21 mm RS-422 Adapter 21 mm Temperature Sensor Unit 76 mm
Cpm1a - MAD01 Input signal ranges: 0 to 10 V, 1 to 5 V, or 4 to 20 mA Output signal ranges: 0 to 10 V, –10 to 10 V, or 4 to 20 mA, Resolution of 1/256 Input signal ranges: 0 to V 5, 0 to 10 V, 1 to 5 V, CPM1A-MAD11 –10 to 10 V, 0 to 20 mA, or 4 to 20 mA Output signal ranges: 0 to 10 V, 1 to 5 V, –10 to 10 V, 0 to 20 mA, or 4 to 20 mA Resolution of 1/6,000
Cpm1a - MAD11 Signal range: 0 to V 5, 0 to 10 V, 1 Signal range: 0 to 10 V, 1 to 5 V, –10 to 10 V, 0 to 20 mA, or 4 to 5 V, –10 to 10 V, 0 to to 20 mA, Resolution of 1/6,000 20 mA, or 4 to 20 mA, The open-circuit detection function Resolution of 1/6,000 can be used with the 1 to 5 VDC and 4 to 20 mA settings.
Cpm1a - 10CDR-j(-V1)/ IR 00003 to IR 00004 0.3 ms 10CDT-D(-V1)/10CDT1-D(-V1) ((1 kHz in Counter Mode)) CPM1A-20CDR-j(-V1)/ IR 00003 to IR 00006 20CDT-D(-V1)/20CDT1-D(-V1)/ 30CDR-j(-V1)/30CDT-D(-V1)/ 30CDT1-D(-V1)/40CDR-j(-V1)/ 40CDT-D(-V1)/40CDT1-D(-V1)
Cpm1a - MAD01 Signal range: 0 to 10 V, 1 to 5 V, or Signal range: 0 to 10 V, 4 to 20 mA, Resolution of 1/256 –10 to 10 V, or 4 to The open-circuit detection function 20 mA, can be used with the 1 to 5 VDC Resolution of 1/256 and 4 to 20 mA settings.
Cpm1a - 10CDR-j(-V1)/10CDT-j(-V1)/10CDT1-j(-V1) CPU Unit 56 mm CPM1A-20CDR-j(-V1)/20CDT-j(-V1)/20CDT1-j(-V1) CPU Unit 76 mm Allow 10 to 15 mm between the Units when installing a Communications Adapter next to the CPU Unit, as shown below.
Cpm1a - TS001/002 Set value Thermocouple Range (°C) Range (°F) 0 K –200 to 1,300 –300 to 2,300 1 0.0 to 500.0 0.0 to 900.0 2 J –100 to 850 –100 to 1,500 3 0.0 to 400.0 0.0 to 750.0 4 to F --- Setting not possible
Cpm1a - TS101/102 Set value Platinum resistance Range (°C) Range (°F) thermometer 0 Pt100 –200.0 to 650.0 –300.0 to 1,200.0 1 JPt100 –200.0 to 650.0 –300.0 to 1,200.0 2 to F --- Setting not possible
Cpm1 - EMU01-V1 Uploads the ladder program and DM 6144 to DM 6655 from the PC to the EEPROM and downloads the ladder program and DM 6144 to DM 6655 from the EEPROM to the PC.